Inspection Photos – Roof Panels

All of the roof panels have been installed as follows: RayCore structural panels with internal 2×8 cut to size to fit over each set of beams Minimum of 6 lag screws (per manufacturer) through

Inspection Photos – Shear-Wall Sheathing

These are the inspection photos for our shear-wall sheathing. 1/2″ OSB Nail schedule 6″ O.C. on the edge, 12″ O.C. in the field 8d 2-1/2″ ring-shank nails Proper gap maintained with Simpson 20-Gauge Plywood

Soffits

Below are pictures of the soffits we built as roof extensions. The insulated roof panels are only located directly over the living areas. These soffits extend up to 5 feet on the front of

11/21/17 – Electrical Soffit Lights

The electrical installation has finally begun with the addition of can lights to our soffits. These lights needed to get installed so the siding contractor can cut out the soffit panels with openings in